Brachial plates

Proximal humeral plate-2 with angle stabilization (titanium) (#1)

Number of holes (left / right): 3-9
Length (mm): 87-159
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: proximal brachial multi-fragment fractures, proximal brachial consolidation trouble, оsteotomy.
Design features: smooth narrowing distal edge to minimize tissue irritation; blocking or compression expand surgical capabilities; multiple points of multidirectional fixation with wide seizure of the proximal brachia and optimal strain distribution.

Proximal humeral plate - 3 with angle stabilization (titanium) (#2)

Number of holes (left/right): 4-9
Length (mm): 140-230
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: proximal brachial multi-fragment fractures, proximal brachial consolidation trouble, оsteotomy.
Design features: smooth narrowing distal edge to minimize tissue irritation; blocking or compression expand surgical capabilities; multiple points of multidirectional fixation with wide seizure of the proximal brachia and optimal strain distribution.

Proximal humeral plate-2 with angle stabilization (titanium - aluminum -vanadium alloy) (#3)

Number of holes (left / right): 3-9
Length (mm): 87-159
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: proximal brachial multi-fragment fractures, proximal brachial consolidation trouble, оsteotomy.
Design features: smooth narrowing distal edge to minimize tissue irritation; blocking or compression expand surgical capabilities; multiple points of multidirectional fixation with wide seizure of the proximal brachia and optimal strain distribution.

Metaphyseal plate-1 for upper extremities with angle stabilization (titanium) (#4)

Number of holes: 6-18
Length (mm): 87-159/86-242
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.

Metaphyseal plate-1 for upper extremities with angle stabilization (titanium - aluminum -vanadium alloy) (#5)

Number of holes: 6-18
Length (mm): 87-159/86-242
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.

Distal humeral plate (titanium) (#6)

Number of holes (left / right): 3-6
Length (mm): 89.5 – 134.5
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: distal brachial fractures.

Distal posterolateral humeral plate-1 with angle stabilization (titanium) (#7)

Number of holes (left / right): 3-14
Length (mm): 68-211
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: supracondylar fractures of the distal brachia; intra-articular fractures of the distal brachia.
Design features: anatomically curved plate minimizes or excludes any need for modeling - 2.7mm and 3.5mm screws make the angle stabilization system for optimal stress distribution; 5 x 2.7mm screws allow to fix low distal fractures (especially in osteoporosis), flat and round forms minimize tissue irritation; composite holes; tapered tip for armpit introduction.

Distal posterolateral humeral plate-2 with angle stabilization (titanium) (#8)

Number of holes (left / right): 3-14
Length (mm): 68-211
Screws: 3.5 mm cortical, 4.0 mm cancellous, 2.4/2.7 mm blocking, 3.5 mm blocking.
Intended use: supracondylar fractures of the distal brachia; intra-articular fractures of the distal brachia.
Design features: anatomically curved plate minimizes or excludes any need for modeling - 2.7mm and 3.5mm screws make the angle stabilization system for optimal stress distribution; 5 x 2.7mm screws allow to fix low distal fractures (especially in osteoporosis), flat and round forms minimize tissue irritation; composite holes; tapered tip for armpit introduction.

Distal medial humeral plate-1 with angle stabilization (titanium) (#9)

Number of holes (left / right): 7-15
Length (mm): 83.5 – 187.5
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: supracondylar fractures of the distal brachia; intra-articular fractures of the distal brachia.