Clavicular plates

S-shaped clavicular plate with angle stabilization (titanium) (#1)

Number of holes (left / right): 7-10
Length (mm): 79-117
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: collar bone fracture.

Upper clavicular plate with angle stabilization (titanium) (#2)

Number of holes (left / right): 6-8.
Length (mm): 94-122
Screws: 3.5. mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: collar bone shaft fracture, collar bone nonunion, wrong union of collar bone fracture.
Design features: plate segments provide possibility of additional modeling; tapered tip facilitates introduction; rounded design of the plate minimizes tissue irritation; screws under different angles diminish risks of the bone splitting in surgery.

Upper clavicular plate with angle stabilization (titanium – aluminum -vanadium alloy) (#3)

Number of holes (left / right): 6-10
Length (mm): 94-150
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: collar bone shaft fracture, collar bone nonunion, wrong union of collar bone fracture.
Design features: plate segments provide possibility of additional modeling; tapered tip
facilitates introduction; rounded design of the plate minimizes tissue irritation; screws under different angles diminish risks of the bone splitting in surgery.

Clavicular plate hook-shaped with angle stabilization (titanium) (#4)

Number of holes (left / right): 4-7
Hook depth (mm): 12, 15, 18
Length (mm): 82.4 – 129.5
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: collar bone lateral third fracture, acromioclavicular joint damage.

Upper clavicular plate with angle stabilization - 3 (titanium) (#5)

Number of holes (left / right): 3-8
Length (mm): 69-135
Screws: 2.7 mm cortical, 2.4 mm blocking, 3.5 mm blocking/cortical.
Intended use: distal collar bone fractures, in consolidation trouble, for osteotomy.
Design features: fixed angle of blocking unit in distal part by means of 2.4mm and 2.7mm screws; six points of fixation with wide seizure of the collar bone distal part and optimal strain distribution; modeling capability.

Upper clavicular plate with angle stabilization -3 (titanium - aluminum -vanadium alloy) (#6)

Number of holes (left / right): 3-8
Length (mm): 69-135
Screws: 2.7 mm cortical, 2.4 mm blocking, 3.5 mm blocking/cortical.
Intended use: distal collar bone fractures, in consolidation trouble, for osteotomy.
Design features: fixed angle of blocking unit in distal part by means of 2.4mm and 2.7mm screws; six points of fixation with wide seizure of the collar bone distal part and optimal strain distribution; modeling capability.