Ulnar and radial bone plates

Proximal dorsal ulnar plate with angle stabilization (# 1)
(Head with 2.7 mm holes, titanium- aluminum -vanadium alloy)

Number of holes (left / right): 2-8
Length (mm): 100-180.6
Screws: 3.5 mm cortical, 4.0 mm cancellous, 2.4 mm blocking, 2.7 mm blocking.
Intended use: ulnar fractures

Proximal plate for radial bone head-1 with angle stabilization (titanium) (#2)

Number of holes (left / right): 2-4
Length (mm): 37.5-55.5
Screws: 2.0 mm cortical, 2.0 mm blocking, 2.4 mm blocking

Proximal plate for radial bone neck - 2 with angle stabilization (titanium) (#3)

Number of holes (left / right): 2-4
Length (mm): 31.5 – 49.5
Screws: 2.0 mm cortical, 2.0 mm blocking, 2.4 mm blocking

Plate-1 (for upper extremities) straight, narrow with angle stabilization (titanium) (#4); titanium- aluminum -vanadium alloy (#5)

Number of holes: 4-14
Length (mm): 60-177

Reconstructive plate (for upper extremities) with angle stabilization (titanium) (# 6); titanium- aluminum -vanadium alloy (#7)

Number of holes: 5-20
Length (mm): 72-282
Screws: 3.5 mm cortical, 4.0 mm cancellous, 3.5 mm blocking.
Intended use: brachium shaft fractures, reconstructive – modeling simplicity allows to use for small bones.

Т- plate-1, right angular (3 holes, head) with angle stabilization (titanium) (#8)

Number of holes (left / right): 3-5
Length (mm): 49-67
Screws: 3.5 mm cortical, 3.5 mm blocking, 4.0 mm cancellous

L– shaped distal radial (2 holes, head) with angle stabilization (titanium) (#9)

Number of holes (left / right): 3-5
Length (mm): 40-58
Screws: 2.4 mm cortical, 2.4 mm blocking, self-tapping
Intended use: distal radial bone fractures

L- plate distal radial (3 holes, head) with angle stabilization (titanium) (#10)

Number of holes (left / right): 3-5
Length (mm): 40-58 mm
Screws: 2.4 mm cortical, 2.4 mm blocking, self-tapping

Palmar Т-plate distal radial with angle stabilization (titanium) (#11)

Number of holes (left / right): 3-5
Length (mm): 43-61
Screws: 2.4 mm cortical, 2.4 mm blocking, self-tapping
Intended use: distal radial bone fractures

Palmar Т-plate distal radial with angle stabilization (titanium) (#12)

Number of holes (left / right): 3-5
Length (mm): 49-67
Screws: 2.4 mm cortical, 2.4 mm blocking, self-tapping

Palmar plate distal radial with angle stabilization (#13) (titanium - aluminum -vanadium alloy)

Number of holes (left / right): 3-7
Length (mm): 50.5 – 85.5
Screws: 2.4/2.7 mm blocking, 3.5 mm blocking, 3.5 mm cortical, 4.0 mm cancellous, 2.7 mm light metal blocking pig
Intended use: intra- and juxta-articular fractures, distal radial bone osteotomy (volar approach).